Digital Temperature Controller (22.5 mm Wide and DIN Track-mounting Type) [E5DC/E5DC-B] (Part Numbers - CAD Download)

Digital Temperature Controller (22.5 mm Wide and DIN Track-mounting Type) [E5DC/E5DC-B]
The E5DC Mounts to DIN Track and Is Ideal for Connections to HMIs and PLCs. It provides the Same Easy Operation and Advanced Performance as the Rest of the E5□C Series.
Models with Push-In Plus Terminal Blocks Added to Lineup.

• A slim body at 85 × 22.5 mm (D × W) that fits into narrow control panels and mounts to DIN Track.
• Removable terminal block for easy replacement to simplify maintenance.
• Select from models with screw terminal blocks and models with Push-In Plus terminal blocks for reduced wiring work.
• No need for power supply and communication line wiring when using connectors with Push-In Plus terminal blocks.
(Maximum connectable units: 16)
• High-speed sampling at 50 ms for applications with high-speed temperature increases.
• Easy connections to a PLC with programless communications.
• Set up the Controller without wiring the power supply by connecting to the computer with a Communications Conversion Cable (sold separately).
Setup is easy with the CX-Thermo (sold separately).
• Models are available with up to 2 auxiliary outputs and 1 event input to complete basic functions.
• A white PV display (height: 8.5 mm) is easy to read when setting up, checking alarms, and making settings in a control panel.

Part Number

Once your search is narrowed to one product,
the corresponding part number is displayed here.

Part Number
E5DC-CX0ASM-015
E5DC-CX0DSM-015
E5DC-CX2ASM-000
E5DC-CX2ASM-016
E5DC-CX2DSM-000
E5DC-CX2DSM-015
E5DC-CX2DSM-016
Part Number
Standard Unit Price
Minimum order quantityVolume Discount
Standard
Shipping Days
?
Control Method Input Method Control Output Number of Control Points
(pcs.)
Failure Detecting Function Setting Method Indicated Temperature Range
(℃)
Acquired Standards Type Power Supply Voltage
(V)
Control Output 1 Control Output 2 Auxiliary output points Event Input
(Point)
Heater Breakage, SSR Fault Detection Capability Width
(mm)
Height
(mm)
Depth
(mm)
Type of Electric Connection External Reset Possible Error Registration Possible With Detachable Clamps Number of Measuring Circuits Number of Contacts as Change-Over Contact Number of Contacts as Normally Closed Contact Number of Contacts as Normally Open Contact

425.20 €

1 7 Days --Current1---UL / CSA / CETemperature Controller / ControllerVAC 100–240Linear voltage outputNANANA------------

425.20 €

1 6 Days --Current1---UL / CSA / CETemperature Controller / ControllerAC/DC24VLinear voltage outputNANANA------------

384.10 €

1 7 Days --Current1---UL / CSA / CETemperature Controller / ControllerVAC 100–240Linear voltage outputNA2 Points (Common)NA------------

419.10 €

1 7 Days --Current1---UL / CSA / CETemperature Controller / ControllerVAC 100–240Linear voltage outputNA2 Points (Common)1------------

384.10 €

1 7 Days --Current1---UL / CSA / CETemperature Controller / ControllerAC/DC24VLinear voltage outputNA2 Points (Common)NA------------

464.90 €

1 6 Days --Current1---UL / CSA / CETemperature Controller / ControllerAC/DC24VLinear voltage outputNA2 Points (Common)NA------------

419.10 €

1 7 Days --Current1---UL / CSA / CETemperature Controller / ControllerAC/DC24VLinear voltage outputNA2 Points (Common)1------------

Loading...

  1. 1

Basic information

Number of Input Points(pcs.) 1

Tech Support

Technical Support