Manufacturer part number: CF310.UL.60.01-6SQ-38
Brand: IGUS
Price: 383.63 €
Delivery time: 5 Days
Overall Length: 38 m
Conductor Cross Section: 6 mm2
Finished outer diameter: 7.5 mm
Minimum bending radius while running: 56.25 mm
Minimum bending radius when fixed: 30 mm
Part Number
Once your search is narrowed to one product,
the corresponding part number is displayed here.
CF310.UL.60.01-6SQ-38
Part Number
|
---|
CF310.UL.60.01-6SQ-38 |
Part Number |
Standard Unit Price
| Minimum order quantity | Volume Discount | RoHS | Overall Length (m) | Conductor Cross Section (mm2) | Finished outer diameter (mm) | Minimum bending radius while running (mm) | Minimum bending radius when fixed (mm) | Conductor resistance (Ω/km) | Reference allowable current value (30°C) (A) | Other standards | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
383.63 € | 1 | 5 Days | 10 | 38 | 6 | 7.5 | 56.25 | 30 | 3.3 | 53 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2249: Used of UL (AWM) cable allowed |
Loading...
Number Of Cores(Core) | 1 | Rated Voltage | 600/1000V | Shield | Tin plated copper braid |
---|---|---|---|---|---|
Properties | Oil Resistance / Weatherproof | Representative Standard | UL / CE / CSA(c-UL) | Sheath (outer coating) color | Black |
Grounding Wire | N/A | Sheath (outer coating) material | Low adhesiveness TPE admixture | Insulation body materials | TPE admixture |
Free span maximum running speed(m/s) | 10 | Slide maximum running speed(m/s) | 6 | Maximum acceleration(m/s2) | 100 |
Stroke | Up to 400m | Other cable properties | Flame retardant and silicone free | Note 1 | Rated voltage: Uo/U (V) Uo = Voltage between conductor and ground, U = voltage between conductors |
This page is Chain Flex CF310.UL- Power Cable, with Shield, part number CF310.UL.60.01-6SQ-38.
You can find the detail information about specifications and dimensions on part number CF310.UL.60.01-6SQ-38.
Configure
Basic Attributes
Overall Length(m)
Conductor Cross Section(mm2)
Finished outer diameter(mm)
Minimum bending radius while running(mm)
Minimum bending radius when fixed(mm)
Conductor resistance(Ω/km)
Reference allowable current value (30°C)(A)
Filter by standard shipping days
Optional Attributes
Part Number |
---|
CF310.UL.100.01-10SQ-11 |
CF310.UL.100.01-10SQ-12 |
CF310.UL.100.01-10SQ-13 |
CF310.UL.60.01-6SQ-39 |
CF310.UL.60.01-6SQ-4 |
CF310.UL.60.01-6SQ-40 |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Standard Shipping Days ? | RoHS | Overall Length (m) | Conductor Cross Section (mm2) | Finished outer diameter (mm) | Minimum bending radius while running (mm) | Minimum bending radius when fixed (mm) | Conductor resistance (Ω/km) | Reference allowable current value (30°C) (A) | Other standards |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
117.97 € | 1 | 5 Days | 10 | 11 | 10 | 8.5 | 63.75 | 34 | 1.91 | 74 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2322: Used of UL (AWM) cable allowed | ||
128.68 € | 1 | 5 Days | 10 | 12 | 10 | 8.5 | 63.75 | 34 | 1.91 | 74 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2323: Used of UL (AWM) cable allowed | ||
139.42 € | 1 | 5 Days | 10 | 13 | 10 | 8.5 | 63.75 | 34 | 1.91 | 74 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2324: Used of UL (AWM) cable allowed | ||
393.72 € | 1 | 5 Days | 10 | 39 | 6 | 7.5 | 56.25 | 30 | 3.3 | 53 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2250: Used of UL (AWM) cable allowed | ||
40.37 € | 1 | 5 Days | 10 | 4 | 6 | 7.5 | 56.25 | 30 | 3.3 | 53 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2215: Used of UL (AWM) cable allowed | ||
403.82 € | 1 | 5 Days | 10 | 40 | 6 | 7.5 | 56.25 | 30 | 3.3 | 53 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2251: Used of UL (AWM) cable allowed |