[Specifications]
・Product type: IR thermometer
・Calibration service: 3 appropriate calibration values in the measuring range of the respective device (-20;0; +60 °C)
・Calibrated to: DAkkS standards, ISO standards, Manufacturer's standards (no certificate)
・Sensor type: K

Part Number

Once your search is narrowed to one product,
the corresponding part number is displayed here.

Part Number
2558118
2837799
2837806
4130474
4130488
4321662
4328074
Part Number
Standard Unit Price
Minimum order quantityVolume Discount
Standard
Shipping Days
?
Calibrated to Power supply (details) Product size (height)
(mm)
Product size (width)
(mm)
Product size (length)
(mm)
Weight
(g)
Accuracy (details) Accuracy (details)
(%)
Accuracy (details)
(°C)
Accuracy (+/-) °C
(°C)
Basic accuracy (+/-)
(%)
Calibration service Display (thermometer) Emission level (max.) Emission level (min.) Emissivity Max. temperature
(°C)
Min. temperature
(°C)
Optics Pick-up time (details) Pick-up time (details)
(ms)
Pick-up time (details)
(s)
Probe thermometer features Reading range - temperature Reading range - temperature
(°C)
Resolution (temperature)
(°C)
Sensor type Temperature resolution
(°C)

273.17 €

1 Available 3 Days Manufacturer's standards (no certificate)2 AA batteries18050160320-± 1-113 appropriate calibration values in the measuring range of the respective device (-20;0; +60 °C)12:10.950.3adjustable from 0.3 to 0.95+550-40---0.5Contact measurement--40 to +5500.1K-

762.28 €

1 Available 3 Days DAkkS standards2 AA batteries25469191965.0--± 1% or 1113 appropriate calibration values in the measuring range of the respective device (-20;0; +60 °C)30:110.10.10 - 1.0+650-4030/1-< 500-Contact measurement-IR: -40 to +650 °C/K-type: -40 to +13720.1K0.1

818.77 €

1 Available 19 Days DAkkS standards2 AA batteries254691911026.0--± 1% or 1113 appropriate calibration values in the measuring range of the respective device (-20;0; +60 °C)50:110.10.10 - 1.0+800-4050/1-< 500-Contact measurement-IR: -40 to +800 °C/K-type: -40 to +13720.1K0.1

166.51 €

1 Available 3 Days DAkkS standards1 x AA battery7585175255Accuracy ± 1.5 °C or ± 1.5% of reading--1.51.53 appropriate calibration values in the measuring range of the respective device (-20;0; +60 °C)10:110.1-+500-3010 : 1< 500 ms (95% of reading)----30 to +500 °C-0.2--

192.52 €

1 Available 3 Days DAkkS standards1 x AA battery7585175255Accuracy ± 1.0 °C or ± 1.0% of reading--113 appropriate calibration values in the measuring range of the respective device (-20;0; +60 °C)12:110.1-+650-3012 : 1< 300 ms (95% of reading)----30 to +650 °C-0.2--

2,601.68 €

1 Available 23 Days ISO standardsLR03 batteries (AAA)17752164322≥ 0°C ±1% or ±1.0 °C.--113 appropriate calibration values in the measuring range of the respective device (-18;0; +60 °C)50:110.10.10 to 1.00+800-4050:1-500-Contact measurement--40°C to +8000.1K-

1,372.39 €

1 Available 9 Days ISO standards2 AA batteries---322≥ 0°C ±1 °C or ±1%--113 appropriate calibration values in the measuring range of the respective device (-18;0; +60 °C)60:110.1-+900-3060:1-<500-Contact measurement--30 to +9000.1K-