Single-phase Overvoltage/Undervoltage Relay [K8DT-VW] (Part Numbers)

Single-phase Overvoltage/Undervoltage Relay [K8DT-VW]
Detect abnormal voltages applies to equipment to protect against equipment failure. Monitor for overvoltages and undervoltages simultaneously with one relay.
• Monitor AC or DC voltages with one relay
• Settings for the operating value, hysteresis, and operating time
• Width of 17.5 mm to reduce space required in panels
• Push-in plus Technology that reduce wiring work
• UL listed for easy shipping to North America
• Double-insertion holes for crossover wiring (all terminals)
• Models added with transistor outputs for superior contact reliability
• RoHS compliant

Part Number

Once your search is narrowed to one product,
the corresponding part number is displayed here.

Part Number
K8DT-VW2CA
K8DT-VW2CD
K8DT-VW2TA
K8DT-VW2TD
K8DT-VW3CA
K8DT-VW3CD
K8DT-VW3TA
K8DT-VW3TD
Part Number
Standard Unit Price
Minimum order quantityVolume Discount
Standard
Shipping Days
?
Voltage Type for Actuating Number of Contacts as Normally Open Contact Rated Control Supply Voltage AC 60 Hz
(V)
Rated Control Supply Voltage DC
(V)
Rated Control Supply Voltage AC 50 Hz
(V)
Response Value Voltage
(V)
Voltage Measuring Range 1
(V)
Single-Phase Hysteresis Possible Contains Function DC-Voltage Hysteresis

185.40 €

1 3 Days AC0100 - 240-100 - 2401 - 1501 - 150truetrue

185.40 €

1 3 Days AC/DC020.4 - 26.420.4 - 26.420.4 - 26.41 - 1501 - 150falsefalse

185.40 €

1 3 Days AC1100 - 240-100 - 2401 - 1501 - 150truetrue

185.40 €

1 3 Days AC/DC120.4 - 26.420.4 - 26.420.4 - 26.41 - 1501 - 150falsefalse

185.40 €

1 3 Days AC0100 - 240-100 - 24020 - 60020 - 600falsefalse

185.40 €

1 3 Days AC/DC020.4 - 26.420.4 - 26.420.4 - 26.420 - 60020 - 600falsefalse

185.40 €

1 3 Days AC1100 - 240-100 - 24020 - 60020 - 600falsefalse

185.40 €

1 3 Days AC/DC120.4 - 26.420.4 - 26.420.4 - 26.420 - 60020 - 600falsefalse

Loading...

  1. 1

Basic information

Application Voltage Monitoring Type of Electric Connection Spring clamp connection With Detachable Clamps false
Number of Contacts as Change-Over Contact 1 Depth(mm) 90 Height(mm) 90
Width(mm) 17.5 Number of Contacts as Normally Closed Contact 0 Max. Permitted Delay-On Energization Time(s) 30
Min. Adjustable Delay-On Energization Time(s) 0.1 Type of Voltage Measuring Range AC/DC Three-Phase Hysteresis Possible false
Three-Phase Under Voltage Possible false Contains Function DC-Under Voltage true Single-Phase Under Voltage Possible true
Three-Phase Over Voltage Possible false Single-Phase Over Voltage Possible true Contains Function DC-Over Voltage true